VP-790 Protocol – API Functions 73
2.65 73BMultiple Unit Horizontal Set
2.65.1 322BbyOsdMultipleUnitHorizontalSet
API index: 3106
Sets the horizontal address of the unit.
Input Parameters
Name Type Range Description
Value UWORD32 0x00-0x03 Horizontal address of the unit. The
actual range is 0x00 to Horizontal
Width – 1.
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise
2.65.2 323BbyOsdMultipleUnitHorizontalGet
API index: 3107
Retrieves the horizontal address of the unit.
Input Parameters
Name Type Range Description
Option BYTE 0: From cache
1: From SPD
Retrieval method
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise
Value UWORD32 0x00-0x03 Horizontal address of unit.
2.65.3 324BbyOsdMultipleUnitHorizontalSave
API index: 3108
Saves the number from cache into the SPD.
Input Parameters
None
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise