VP-790 Protocol API Functions 99
2.93 101BPTZ Settings Scope
2.93.1 402BbyOsdPtzSettingSet
API index: 3222
Sets the scope of the PTZ settings from global to Per-mode.
Input Parameters
Name Type Range Description
Value UWORD32 0: Use Globally
1: Use Per-Mode
Scope of PTZ settings.
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise
2.93.2 403BbyOsdPtzSettingGet
API index: 3223
Retrieves the PTZ scope setting from cache or from the SPD.
Input Parameters
Name Type Range Description
Option BYTE 0: From cache
1: From SPD
Retrieval method
None
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise
Value UWORD32 0: Use Globally
1: Use Per-Mode
Scope of PTZ settings.
2.93.3 404BbyOsdPtzSettingSave
API index: 3224
Saves the PTZ scope setting from cache into the SPD.
Input Parameters
None
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise