RC-43T - Connecting the RC-43T
5.1 K-NET Wiring
The K-NET connector on the RC-43T must be connected to a room controller via a
four wire cable as shown in Figure 7 and Figure 8.
Figure 7: RC-43T K-Net Wiring US Version
Figure 8: RC-43T K-Net Wiring EU Version
Note: The RC-43T is always device ID 2 on the K-NET bus and cannot be
changed.
To connect the RC-43T to a room controller:
Connect pin 1 on the K-NET connector to pin 1 on the room controller K-NET
connector (+12V to +12V)
Connect pin 2 on the K-NET connector to pin 2 on the room controller K-NET
connector (A to A)