Operating the VP-417 Video to PC/HD/DVI Scaler
6.2 Using the OSD
You can use the OSD to set a wide variety of parameters.
When using the OSD, the front panel buttons operate in the following manner:
• MENU: Opens the OSD main menu (see
Table 4). Press a second time to
close the OSD
• ENTER: Selects the highlighted menu option or parameter
• – : Steps up through the menu options or decrements a parameter value
• + : Steps down through the menu options or increments a parameter value
Example of Setting a Parameter
The following steps are an example of setting parameters to increase the saturation
on the display:
1. From normal operation
1
2. Press the + or – button to highlight SATURATION.
SATURATION changes to green when highlighted.
, press MENU.
The OSD Main Menu appears on the screen.
3. Press ENTER.
The saturation parameter changes to red.
4. Press the + button to increase the value or the – button to decrease the value.
5. Press ENTER to set the value.
The saturation parameter changes to white.
6. To return to normal operation, either:
Press MENU
Wait until the menu times out automatically
6.2.1 The Main Menu
Table 4 defines the Main Menu parameters and functions.
Table 4: The Main Menu Parameters and Functions
Parameter Function Value Range Factory
Default
CONTRAST Adjusts the contrast 0 to 255 128
BRIGHTNESS Adjusts the brightness 0 to 255 128
SATURATION Adjusts the saturation 0 to 255 128
HUE Adjusts the hue -128 to 128 (Not available in PAL) 000
AUTO SYNC OFF Turns auto sync on/off
ON/OFF OFF
ASPECT RATIO Adjusts the aspect ratio of the
output
FULL/4:3/16:9 FULL
OVER SCANNING Adjusts the over scanning value OFF/5%/10%/15%/20% 5%
NOISE REDUCTION Adjusts the noise reduction filter Off/Typ/Min/Max Typ
1 That is, the user is not within the OSD menu
2 When on, the VP-417 disables its output syncs after a few minutes when no input source is detected. This feature is useful for
applications where the projector should automatically shut down when no source is present
Comentários a estes Manuais