VP-728 - VP-728 Communication Protocol 51
51
11 VP-728 Communication Protocol
Serial Configuration:
Baud rate: 9600 (Bits per second)
Data bits: 8bits
Parity: None
Stop bits: 1bit
Communication confirmation:
Send: CR
Reply: CR>
Set Command:
Send: YControl_TypeFunctionParamCR
Reply: ZControl_TypeFunctionParamCR>
Get Command:
Send: YControl_TypeFunctionCR
Reply: ZControl_TypeFunctionParamCR>
Example: set Input 1 Source Type to Component
Send: Y000CR
Reply: Z000CR>
Example: get current Input 1 Source Type
Send: Y10CR
Reply: Z100CR >
Definition:
: ASCII Code 0x20
CR: Ascii Code 0x0D
Go to our Web site at http://www.kramerelectronics.com to check for the